Colorectal Case 28

Mr. Peter Borch-Johnsen
RN, M.Sci, PhD- Student
Department of Medicine
Ersta Hospital
Department of Medical Sciences
Uppsala University
Scope: PCF-HQ190l
Organ: Colon, sigmoid
Patient information: N/A
Medical history: N/A
Case Video
An approximately 20 mm pedunculated polyp (Paris Ip, JNET 2a) at the distal sigmoid with a slightly eroded and irregular surface due to friction caused by a high peristaltic activity at this level. Underwater colonoscopy causes the polyp to lift up and can be easily captured with the snare. Polypectomy was performed in air phase (Co2). Diathermia resection went rather fast resulting in a pulsating bleeding. RDI mode 1 made easier to detect and coagulated with the tip of the snare. RDI reduced the time to manage the bleeding avoiding major complications.
Overall Comment
RDI mode 1 seems to enhances the visibility of the bleeding source making haemostasis quicker and easier. It has also a calming effect on the endoscopist and the waken patient as the bleeding perceived as less dramatic.
* Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer
Mr. Peter Borch-Johnsen Case 29: Multifocal Anal Squamous Intraepithelial Lesions (ASIL) with low and high-grade dysplasia